Product description:
PROFINET slave unit is now available for CKD's 4GR Series solenoid valves, which have high reliability (durability: 100 million operations) and environmental resistance. As for safety, in addition to those safety features of 4GR Series solenoid valves (such as a function that prevents accidental activation of the manual override), the slave unit's power supplies for control and load are separated so that the solenoid valve power can be turned off without interrupting communication in an emergency. Furthermore, this slave unit is easy to use since it is equipped with a general-purpose RJ45 connector for its network port and has a counter function that measures the number of times the unit is used and the length of time it is energized.
Technical data and key features
* Installation space: Compact communication interface (21 mm wide) but supports 32 output points
* Versatility: RJ45 connector for network port
* Wiring methods: Linear, star, and ring (MRP) topologies
* Maintenance considerations: Separate power supply for valve replacement during communication; Slot-in structure for easy replacement of communication interface
* Applicable cylinder size: Up to 100 mm in diameter
* Valve durability: 100 million operations (4G1 single solenoid valve)