Skip to main content
 Back to list

Fire Resistant Foundation Fieldbus H1 - 50076LB

Classification:
Product name:
Fire Resistant Foundation Fieldbus H1 - 50076LB

Order number:
50076LB

Shortdescription:
1PR X 18AWG MGT/XLPE/OS/LSZH/SWB/LSZH

Product types:
Cables/Connectors

Technology & Profiles:
PROFIBUS

Certification number:

Company:
Belden Hirschmann Industries (Suzhou) Ltd.

333 Yanhu Road, Huaqiao Town,
215332 Kunshan City
China

Zhao Heyang
Tel +86 18662550172
https://www.belden.com
Heyang.Zhao(at)belden(dot)com

Illustration:
Product description:

Construction:

Design: 1 Pair 18 AWG 
Conductor: Stranded Tinned Copper
Fire Protection Barrier : Mica Glass Tape (MGT) 100% coverage
Insulation: XLPE (Electron ‐ Beam Cross linked PE)
Shielding: Overall Beldfoil® Aluminium Foil ‐ Polyester Tape with 100 % Coverage
Outer Jacket: Low Smoke Zero Halogen/Low Fire Hazard
Armour : Galvanized steel wire braid armour (GSWB)
Minimum Bend Radius : 12 X OD
EU RoHS compliance: Yes

Mechanical Properties:

Flame Retardancy: IEC 60332‐3‐22 Category A IEC 60332‐1‐2
Operating temperature: -40°C To +90°C
Fire Resistance / Circuit Integrity : IEC 60331‐23 (750°C for 90 minutes)
Oil Resistance : ICEA S 73‐532 IRM 902
UV / Sun Light Resistance: UL 1581
Light transmittance property as per IEC 61034-2

Electrical Properties as per IEC 61158-2 Type-A, FF-844:

Voltage Rating: 300 V
Impedance (31.25 KHz): 100 ± 20 Ohms
Attenuation (39 KHz): <= 3 dB/KM
Mutual Capacitance @ 1KHz ≤ 80 pF/m
Max. Propagation Delay Change (7.812 ~ 39.06) KHz : 1.7 μS/KM

Target Application:

Foundation Fieldbus is the dominant industrial network in the oil,gas and petrochemical industries as well as most process industries. Fieldbus is an all-digital,serial,two way communications protocol that standardizes the interconnection of field devices at a communications rate of 31.25 kB/s. The Field devices are accessible communication netowrks(running at 1 or 2.5Mb/s), through linking devices. These cables have electron beam(E-Beam) XLPE insulation that offers lower capacitance, longer run lengths and improved cut through and chemical resistance compared to other insulations. These cables are fire resistant as per IEC-60331-23 for 750 deg C for 90 minutes. Type A, H1 registered cable.

Flammability, LS0H, Toxicity Testing:

Smoke Density ASTM D2843 : Max. 40%
Halogen Acid Gas IEC 60754‐1 : Max. 0.5%
Toxicity Index EN 50305 / NF F63‐305 (ITC)< 5
pH & conductivity as per IEC 60754-2

Reference Standards:

• IEC 60092‐376, EN 50288‐7, IEC 61158‐2, FF 844, IEC 60331‐23, BS 6387
• BS EN 50290‐2‐29, BS EN 50290‐2‐27, IEC 60092‐359, UL 1581, ASTM D 2843, EN 50305, NF F63‐305
• IEC 60332‐1‐2, IEC 60332‐3C, IEC 60332‐3A, IEC 60754‐1, IEC 60754‐2, IEC 61034‐2, ICEA S 73‐532

Links:
 Back to list

PROFIBUS ist ein standardisiertes, offenes, digitales Kommunikationssystem für alle Anwendungsbereiche der Fertigungs- und Prozessautomatisierung.

 

PROFINET ist der innovative offene Standard für Industrial Ethernet. Es erfüllt alle Anforderungen der Automatisierungstechnik.

 

MTP (Module Type Package) ermöglicht eine modulare Produktion, bei der einzele Bausteine flexibel kombiniert werden können.

IO-LINK ist eine eigenständige Sensor/Aktor-Interface-Lösung für den Einsatz in allen Automatisierungstechniken.

 

omlox ist ein offener Technologiestandard für Echtzeit-Indoor-Lokalisierungssysteme in der industriellen Fertigung.